Runnable: Set Deactivate Condition
The module sets attributes for the deactivation condition, which can be read with the module info.DeactivateConditionRead.
Designation
- Name
- mc.DeactivateConditionSet
- Aliases
- RunnableDeactivateConditionSet
Configuration
- Optionen
- Test mode (
test-mode
) - Activates a simulation mode
- Condition (
condition
) - Selection of deactivate conditionMögliche Werte: Never (
never
), After error-free execution (error_free_run
), After error-free restart (error_free_restart
), Always (always
)
- Days of delay (
days
) - Number of days to wait before the task is deactivated
- Task state (
state
) - Task state is accepted as faultlessMögliche Werte: <Leerzeichen>, ANY_ABEND (
ANY_ABEND
), ANY_ABEND_EXCEPT_FAULT (ANY_ABEND_EXCEPT_FAULT
), ANY_EXCEPT_FAULT (ANY_EXCEPT_FAULT
), ANY_OK (ANY_OK
), ANY_OK_OR_UNBLOCKED (ANY_OK_OR_UNBLOCKED
), ANY_SKIPPED (ANY_SKIPPED
), ENDED_CANCEL (ENDED_CANCEL
), ENDED_EMPTY (ENDED_EMPTY
), ENDED_ESCALATED (ENDED_ESCALATED
), ENDED_INACTIVE (ENDED_INACTIVE
), ENDED_INACTIVE_MANUAL (ENDED_INACTIVE_MANUAL
), ENDED_NOT_OK (ENDED_NOT_OK
), ENDED_NOT_OK_SYNC (ENDED_NOT_OK_SYNC
), ENDED_OK (ENDED_OK
), ENDED_OK_OR_EMPTY (ENDED_OK_OR_EMPTY
), ENDED_OK_OR_INACTIV (ENDED_OK_OR_INACTIV
), ENDED_OK_OR_UNBLOCKED (ENDED_OK_OR_UNBLOCKED
), ENDED_SKIPPED (ENDED_SKIPPED
), ENDED_SKIPPED_CONDITIONS (ENDED_SKIPPED_CONDITIONS
), ENDED_SKIPPED_SYNC (ENDED_SKIPPED_SYNC
), ENDED_TIMEOUT (ENDED_TIMEOUT
), ENDED_TRUNCATE (ENDED_TRUNCATE
), ENDED_UNDEFINED (ENDED_UNDEFINED
), ENDED_VANISHED (ENDED_VANISHED
), FAULT_ALREADY_RUNNING (FAULT_ALREADY_RUNNING
), FAULT_NO_HOST (FAULT_NO_HOST
), FAULT_OTHER (FAULT_OTHER
), USER_100_200 (USER_100_200
), USER_147 (USER_147
), USER_201_299 (USER_201_299
), USER_300 (USER_300
), USER_500_600 (USER_500_600
)